SAE J1939-73 Diagnostic Layer
J1939/73 specifies the diagnostic layer for a J1939 network and is the only application layer published and supported for J1939. This specification is responsible for defining all diagnostic layer SPNs and PGNs. J1939-73 defines messages for active faults, passive faults, and clearing faults. Also messages for OBD-2 compliance and flash bootloader operation (i.e. erase and programing of flash).
PGN 65226 Active Diagnostic Codes
Transmission Repetition: | See J1939-73 spec |
Data Length: | Variable |
Default Priority: | 6 |
Parameter Group Number: | 65226 |
Start Position | Length | Parameter Name | SPN |
1.8-1.7 | 2 bits | Malfunction Indicator Lamp Status | 1213 |
1.6-1.5 | 2 bits | Red Stop Lamp Status | 623 |
1.4-1.3 | 2 bits | Amber Warning Lamp Status | 624 |
1.2-1.1 | 2 bits | Protect Lamp Status | 987 |
3-6 | 4 bytes | DTC | n/a |